EMX-17092


+
  • undefined
  • undefined

Name  EMX-17092

 

It is applicable to polycrystalline or monocrystalline solar panel, or indoor DC power charging.

 

No.

Function description and scope of application

1

It is applicable to polycrystalline or monocrystalline solar panel, or indoor DC power charging.

2

The internal battery is in three-string lithium battery structure.

3

Three red LEDs indicate charge and discharge capacity, and one double-color LED indicates the charging state;

4

It has special heavy current USB step-down circuit, and thus, is applicable to charging of lithium battery phone and other digital products.

5

It is provided with one-way 19V/4A DC output, and thus, is suitable for charging 19V notebook computer.

6

It has accurate over-charge and over-discharge protection device and overload protection, short-circuit protection and other functions, so as to guarantee the safety in use.

 
Size PCBA 1: 120mm*4mm8*20mm
PCBA 2: 120mm*26mm*18mm
Characteristics Portable


 Main Parameters 
 

Content Specification requirements Detailed function description
Maximum input charging voltage 14--18V  /5A  
Maximum charging current 5A  5A constant current charging current
Charge mode PWM charge mode  
USB output 2*2 parallel output is provided, the total current is 2.0A, and the maximum current is 2.5A. When loading 2A, its voltage is not less than 4.5A, and the maximum starting current is 2.1A.
Charging indication 4 nixie tubes indicate the battery, and one double-color LED indicates the charging and discharging state. LED indication
Maximum output current It requires that the output current is 9A (calculated value)  
Battery capacity indication 30%,60%,100%  
Over-charge protection voltage Actual battery voltage: 12.75V  
Low voltage over-discharge alarm indication voltage ----- -------
Over-discharge protection voltage 8.4V When it is not charged, the battery recovery voltage must be less than this voltage, and the battery voltage reaches the recovery voltage and the output work can be recovered only when charging is activated.
Over-discharge recovery voltage protection 9V  
Charging reverse connection protection Available  
Standby current when opening the battery indication, but having no load (when the main switch is on) ≤20MA  
Opening battery indication (when the main switch is off) ≤200uA  Calculate according to the standard of solar panel for 8V/60W.
USB output conversion efficiency ≥85%  

 