Name EMX-13002
NO. | Function description and scope of application |
1 | O2 MICRO scheme is adopted. |
2 | The number of strings supported by it is 6-12 strings (6-12S). |
3 | The continuous charging current is 5A, and the discharging current is 15A. |
4 | The protection parameter can be adjusted through software. |
5 | It is applicable to the cells with different chemical properties. |
6 | Such as ternary lithium, lithium cobaltate, lithium manganate, lithium iron phosphate, lithium titanate and other cells. |
Size | 85*45*14MM(L*W*H) |
Characteristics | The protection parameter points can be set by programming. It supports I2C communication, and has the volumeter. |
Main Parameter
Protection of IC scheme:O2 MICRO | Parameter Value | |||
Protection parameters can be set | Min | Type | Max | Unit |
Battery Links | 6 | 12 | S | |
Output Discharging Current | Charging 5A/Discharge 15A | 15 | A | |
(3.2V) Current consumption (Operation) | 600 | 1500 | uA | |
Impedance | 15 | 30 | mΩ | |
Over charge detection voltage | 3.7 | 3.75 | 3.8 | V |
Over charge release voltage | 3.55 | 3.6 | 3.65 | V |
Over discharge detection voltage | 2.35 | 2.4 | 2.45 | V |
Over discharge release voltage | 3.15 | 3.2 | 3.25 | V |
Over charge detection current | 6 | 8 | 10 | A |
Over current detection current | 55 | 60 | 65 | A |
Over charge detecion delay | 1 | S | ||
Over discharge detection delay | 0.5 | S | ||
Over current detection delay | 256 | mS | ||
Short delay | 512 | uS | ||
Equilibrium voltage | 3.5 | 3.55 | 3.6 | V |
Equilibrium current | 50 | 60 | 70 | mA |
Over temperature protection | 70 | ℃ | ||
Thermal recovery | 65 | ℃ | ||
Low temperature recovery | -20 | ℃ | ||
Low temperature protection | -15 | ℃ | ||
PCB Size | 85*45*1.6MM(L*W*H) | MM |