Name EMX-13021
NO. | Function description and scope of application |
1 | Seiko scheme is adopted. |
2 | The number of strings supported by it is 4 strings (4S). |
3 | The continuous charging and discharging current is 2A. |
4 | The protection parameter is protected through hardware. |
5 | It is applicable to lithium iron phosphate cell (different types of chips can be replaced to be suitable for different cells). |
Size | 51.15*16*3MM(L*W*H) |
Characteristics | The protection scheme of small-size lithium iron phosphate cell is provided. |
Main Parameter
Protection of the IC scheme: Seiko | Parameter Value | |||
Protection parameters can be set | Min | Type | Max | Unit |
Battery Links | 4 | S | ||
Output Discharging Current | 2 | 3 | A | |
Current consumption (Operation) | 12 | 35 | uA | |
Impedance | 50 | 70 | mΩ | |
Over charge detection voltage | 3.85 | 3.9 | 3.95 | V |
Over charge release voltage | 3.75 | 3.8 | 3.85 | V |
Over discharge detection voltage | 2.2 | 2.3 | 2.4 | V |
Over discharge release voltage | 2.6 | 2.7 | 2.8 | V |
Over discharge detection voltage | 0.275 | 0.3 | 0.325 | V |
Over current detection current | 10 | 12 | 14 | A |
Over charge detecion delay | 0.92 | 1.15 | 1.4 | S |
Over discharge detection delay | 110 | 144 | 180 | mS |
Over current detection delay | 6 | 9 | 12 | mS |
Short delay | 500 | uS | ||
Equilibrium voltage | / | / | / | V |
Equilibrium current | / | / | / | mA |
Over temperature protection | / | / | / | ℃ |
Thermal recovery | / | ℃ | ||
Low temperature recovery | / | ℃ | ||
Low temperature protection | / | ℃ | ||
PCB Size | 51.15*16*0.8MM(L*W*H) | MM |