HOT-LINE
EMX-15031
Name EMX-15031
| NO. | Function description and scope of application |
| 1 | Ricoh scheme is adopted. |
| 2 | The number of strings supported by it is 2 strings (2S). |
| 3 | The continuous charging and discharging current is 2A. |
| 4 | The protection parameter is protected through hardware. |
| 5 | It is applicable to ternary lithium cell (different types of chips can be replaced to be suitable for different cells). |
| Size | 40.5*7.1*3MM(L*W*H) |
| Characteristics | The protection parameter points can be set by programming |
Main Parameter
| IC: Ricoh protection scheme | Parameter Value | |||
| Protection parameters can be set/span> | Min | Type | Max | Unit |
| Battery Links | 2 | 串S | ||
| Output Discharging Current | 2 | A | ||
| Current consumption (Operation) | 5 | 15 | uA | |
| Impedance | 50 | 75 | mΩ | |
| Over charge detection voltage | 4.24 | 4.29 | 4.34 | V |
| Over charge release voltage | 4 | 4.05 | 4.1 | V |
| Over discharge detection voltage | 2.9 | 3 | 3.1 | V |
| Over discharge release voltage | 3.1 | 3.2 | 3.3 | V |
| Over discharge detection voltage | 0.18 | 0.2 | 0.22 | V |
| Over current detection current | 4 | 7 | A | |
| Over charge detecion delay | 0.5 | 1 | 1.5 | S |
| Over discharge detection delay | 89 | 128 | 167 | mS |
| Over current detection delay | 8 | 12 | 18 | mS |
| Short delay | 500 | uS | ||
| Equilibrium voltage | / | / | / | V |
| Equilibrium current | / | / | / | mA |
| Over temperature protection | / | / | / | ℃ |
| Thermal recovery | / | ℃ | ||
| Low temperature recovery | / | ℃ | ||
| Low temperature protection | / | ℃ | ||
| PCB Size | 40.5*7.1*0.8MM(L*W*H) | MM | ||